M-Series Meters FAQ

Below you will find a trouble shooting guide for our most frequently asked questions regarding our M Series Meters.

TROUBLE SHOOTING GUIDE
PROBLEM PROBABLE CAUSE TO CHECK TO REPAIR
No pulse signal Meter not operational Foreign matter restricting meter movement. Remove Obstruction.
       
  Incorrect Wiring ME Series meters (check polarity) black: -12 VDC, white: input signal, red: +12 VDC.
MR Series meters (non polar connection) -12 VDC input signal.
Make Proper Connections.
       
  Non-Functional Sensor ME Series meters - check for +12 VDC.
MR Series meters - check for continuity.
Contact Hays
       
Meter Runs in Reverse Meter improperly installed.  Flow in wrong direction Be certain arrow on meter body is in direction of flow. Install meter in proper direction.
       
Inaccurate Metering Not enough straight pip between meter and flow disturbance Check distance of straight upstream piping.  Should be a minimum of 5 pipe diameters Re-install at proper distance.
       
Water Visible This is normal. (Wet Dial Meter)    
       
Air Bubble Air is trapped during installation   Invert meter.  Allow water to flow through meter. Rotate Meter to original position and resume operation.